STC compliance, audits, clawbacks and fraud

Does AS/NZS 5033 affect STC eligibility, and what counts as non-compliant?

Short answer

Yes. Small-scale solar must be installed to the relevant standards, including AS/NZS 5033 for the PV array, to be eligible. DC isolator labelling and shutdown arrangements are common audit failures, usually fixed by rectification.

Written and checked by the Energy Merchants desk · Reviewed 3 October 2026 · For installers

To create STCs for a rooftop solar system, the installation has to meet the standards and regulations that apply. AS/NZS 5033 covers the installation and safety requirements for PV arrays. If a system does not comply, the claim is at risk.

Why a standard decides a certificate

The installer declaration for each claim states that the system complies. An audit tests that statement. A system that fails the standard is a system that was declared wrongly, so the certificates are exposed. The scale of the consequence depends on how serious the failure is. See what happens when an install fails an audit.

What auditors check under AS/NZS 5033

  • DC isolator. A correctly rated, correctly placed isolator, with the right label at each point.
  • Labelling. Warning labels on the array, isolators, junction boxes and switchboards. These show up in photos.
  • Cables. Protected, supported and routed to avoid damage, with proper connectors.
  • Earthing and bonding. Correct, tested and recorded.
  • Array mounting. Fixings suited to the roof and wind region.

Rapid shutdown

Some installations now need arrangements that de-energise or reduce voltage on roof circuits in an emergency. Whether it is required depends on the edition of the standard in force, the system design and local rules, so confirm with your state’s electrical regulator and the standard itself. If your design includes it, photograph the devices and labels.

Common non-compliance triggers

Photos in audits show the same few faults: missing or faded labels, a DC isolator in an unsuitable location, unprotected cables on the roof and incomplete test records. The Clean Energy Regulator and SAA have both pushed labelling training because of the frequency. See the CER’s compliance priorities.

From the desk: Carry a label kit for every job and photograph labels last, after any adjustments. Labels fitted at the end are the ones that are legible in the photo.

What this means for installers

Treat the standard as part of the claim, not as separate from it. Build the labelling photos into your checklist, and make sure the installer who signs actually did the compliance checks. Batteries have their own standard, covered in AS/NZS 5139 battery installation.

For the wiring and inverter standards, see AS/NZS 3000 and 4777. The photo list is in the STC photo requirements, and the pillar page is STC trading. A pre-check at Energy Merchants flags missing label photos before lodgement.

Keeping up with the standard

Editions of the standard change, and so do state electrical regulator notices. Build a yearly review into your calendar: read the current requirements, compare them with your standard job template and update the template. Share the update with every installer and subcontractor, because the weakest crew sets your audit result.

Follow-up questions

People also ask

What does an audit look at for AS/NZS 5033?
Typically DC isolator type and labelling, cable protection and routing, earthing and bonding, and warning signs, using photos and sometimes inspection.
Is rapid shutdown required for all systems?
Requirements depend on the edition of the standard, the system type and the jurisdiction. Check the current AS/NZS 5033 and your state's electrical rules.

Got a claim to lodge this week?

Sign up today. Your account manager calls with your rate card and your first claim can be settled within days.

Call the deskStart trading