AS/NZS 4777.2

AS/NZS 4777.2 is the Australian and New Zealand standard for grid-connection of energy systems via inverters. It sets the inverter's required behaviour, including voltage response modes and protection settings, so solar and battery systems stay stable on the network.

Written and checked by the Energy Merchants desk · Reviewed 3 October 2026

AS/NZS 4777.2 is the standard that says how an inverter must behave when it is connected to the grid. It is the inverter-requirements part of the 4777 series. Part 1 covers the installation requirements, and the 2020 revision of part 2 added tighter response settings.

Inverters are tested to it and listed against it. For the network operator the aim is simple: thousands of rooftop systems should not push voltage out of range or fail in ways that cascade.

What it requires

  • Anti-islanding protection, so the inverter shuts down when the grid goes down, unless it is a designed backup mode.
  • Voltage response modes, volt-var and volt-watt, which adjust reactive and real power when local voltage rises.
  • Frequency response and ride-through settings.
  • Regional setting profiles, with Australia A, B and C applying across different networks, which the installer selects at commissioning.

In practice

Installers meet 4777.2 as a commissioning step. The inverter must be set to the profile the distributor requires, and the connection application usually records it. See grid connection application. Getting the region wrong is a classic reason for a distributor to bounce a job.

For the certificate claim, the inverter must be on the approved list with a compliant model, and the paperwork must match the equipment on site. The STC photo requirements cover the inverter label shot.

Common confusion

4777.2 is not AS/NZS 5139. One is how the inverter talks to the grid. The other is how a battery is safely installed. A hybrid inverter and battery job needs both. See hybrid inverter.

It is also not a flexible export scheme. A dynamic operating envelope is a network signal, and the inverter must be capable of responding to it, which is a separate requirement.

From the desk. Record the regional setting you selected on the job sheet. If the distributor queries it months later, you will have the answer.

See STC trading for the claim process and the glossary for more terms.